Selling in NC
Heated square footage for a North Carolina listing
Short answer
In North Carolina, a listed home's heated living area must be space that is heated by a permanent system, finished like the rest of the house, at least seven feet high, and reached directly from other living area. Brokers may not copy the figure from tax records, an old appraisal, a past MLS listing or the plans: they measure it or hire a qualified professional, under the NCREC guidelines or ANSI Z765.
What counts as heated living area in NC?
The NC Real Estate Commission's Residential Square Footage Guidelines count space that meets four tests together. It is heated by a conventional system permanently installed in the home, not a fireplace or a portable heater. It is finished, with walls, floors and ceilings of normal interior materials. It has a ceiling at least seven feet high, or six feet four inches under beams and ducts. And it is directly accessible from other living area, through a door or a heated hallway or stair. Garages, carports, porches, decks and balconies are never living area, however nicely they are finished.
How are sloped ceilings and bonus rooms treated?
A room with a sloped ceiling counts down to the point where the ceiling drops below five feet, but only if at least half of the room's finished floor has a ceiling of seven feet or more. A bonus room over a garage counts when it is heated by the home's system, finished and reached by a heated stair or hallway. A room you can only reach by walking through an unfinished attic or storage area does not meet the access test.
Can a listing agent use the tax record figure?
No. The Commission's guidance is explicit that a broker may not rely on the seller's word, an appraisal made before the listing, a previous MLS entry, tax records or the original blueprints of a finished house. The broker either measures and calculates the heated living area, or hires a qualified professional and reviews the result. If the figure cannot be verified, the Commission's advice is to leave it out of the advertising, because heated living area is a material fact and misreporting it has led to many disciplinary actions.
NCREC guidelines or ANSI Z765?
Brokers may use either, or another recognized professional standard. The main practical difference is below-grade space. The NCREC guidelines let qualifying finished space be reported as one heated living area whether it is above or below grade. ANSI Z765 requires above-grade and below-grade areas to be reported separately, and calls a whole floor below grade if soil sits against any of its exterior walls. Appraisers working on loans sold to Fannie Mae must use ANSI. For a home with a finished basement on a sloping Asheville lot, the two methods can give noticeably different headline numbers, so the method should be stated next to the figure.
What does a professional measurement give the agent?
A drawn floor plan with exterior dimensions, the heated living area and the unheated areas shown separately, the calculations behind them, and a note of the standard used. That is the record that answers a buyer, an appraiser or the Commission if the figure is ever questioned, and the plan doubles as a listing image buyers actually look at.
At a glance
Side by side
| NCREC guidelines | ANSI Z765 | |
|---|---|---|
| Mainly used by | Brokers listing homes for sale or rent | Appraisers, lenders, Fannie Mae and Freddie Mac |
| Below-grade space | May be combined into one heated living area | Reported separately from above-grade area |
| Minimum ceiling height | 7 ft, 6 ft 4 in under beams and ducts | Same sloped-ceiling rule |
| Condominiums | Measured from inside, walls not added | Not intended for condos |
| Calculations | Recommended to show | Must be shown |
Questions
Common questions
Do North Carolina agents have to report square footage?
No. The Real Estate License Law does not require a broker to report square footage. But once a figure is advertised it must be accurate, and an inaccurate heated living area can be treated as a misrepresentation under N.C.G.S. 93A-6(a)(1).
Does an unpermitted finished room count?
Under the NCREC guidance an unpermitted area is identified separately, and the broker must tell prospective buyers there is no permit for it. We show such areas as their own line on the plan so the agent can disclose them clearly.
Which standard do you measure to?
We measure residential listings to ANSI Z765 as standard and can also state the heated living area under the NCREC guidelines. The plan says which method was used, so the number can be defended later.